Bogen PM-3000 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Égalisateurs audio Bogen PM-3000. Bogen PM-3000 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 2 - User’s Guide

Quick StartBasic Wiring1. Temporarily set the AUX INPUT TRIMcontrols on the rear panel to their fullcounterclockwise position. Trims willbe adjusted

Page 3

Quick StartFactory Programmed ConfigurationWhen the ProMatrix unit is first powered up, the factory default settings areloaded. The factory default p

Page 4

Quick StartBasic OperationThis section will show you how to:• Apply power to the unit• Understand the Control Panel (See page 12 for full description)

Page 5 - Contents

Quick StartTo Control VolumeNote: Changing any of the volume, bass or treble levels willeffect all inputs associated with that amp/channel channel.Tur

Page 6 - Unpacking

Quick StartTo Select a Specific InputThe ProMatrix unit is normally set to monitor input activity and, based on thedefault or installer-created priori

Page 7 - Introduction

Quick StartAux Input Trim AdjustmentBy adjusting the Trim controls as follows, inputs with different signal levelsare set approximately equal within t

Page 8

Rear Panel Model PM-30001. MIC A — Female XLR-type connector for balanced,LO-Z microphone input. Pin 1 is Gnd.2. MIC B/TEL B — Screw terminal Input

Page 9

12Rear Panel Model PM-31801. MIC A — XLR-type connector for balanced, LO-Z microphone input. Pin 1 is Gnd.2. MIC B/TEL B — Input for Lo-Z balanced m

Page 10 - Quick Start

Front Panel1. Alphanumeric display area.2. AUX A/B/C/D — Input selector buttons & indicators.3. AUTO — Controls manual or automatic input select

Page 11

14Infrared Remote ControllerThe infrared remote controller provides all of the functions of the front panel.Before using the controller, install two A

Page 12

Models PM-3000 & PM-3180User’s GuidePart No. 54-5003-029707

Page 13

Wiring InformationOutputs For PM-3000 PreamplifierEach preamplifier channel has its own balanced output terminals and unbal-anced RCA output jacks on

Page 14

Wiring InformationOutputs For PM-3180 AmplifierEach amplifier channel has its own output terminal strip on the rear panel.Each terminal strip can hand

Page 15

Wiring InformationAUX InputsUnbalanced input sources other than microphones are connected to theAUX INPUT jacks. The output lead from the source must

Page 16 - Rear Panel Model PM-3000

Wiring InformationMIC InputsMic A Pin 1 is GNDPin 2 (+)Pin 3 (-)Mic B/TelProgram the unit for correct switch precedence or use VOX precedence ifno swi

Page 17 - Rear Panel Model PM-3180

User OperationThe ProMatrix Control PanelThe control panel is the interface between the user and the unit functions.Since there are three channels (am

Page 18 - Front Panel

User OperationTo Control Volume, Bass or TrebleNote: Changing any of the volume, bass or treble levels will effect allinputs associated with that ampl

Page 19 - Infrared Remote Controller

User Operationthe current input was lowered by. This is because the levels set by the user aretemporary and the ProMatrix always strives to maintain

Page 20 - Wiring Information

ProgrammingEnter Programming ModeThe programming mode lets the installer custom configure the ProMatrixunit. The installer uses the programming butto

Page 21

ProgrammingProgramming MenuThe ProMatrix programming menu is illustrated below:Press PROG000 (or user-selected password)Assignment Set priority level

Page 22

ProgrammingAssignmentThe ASSIGNMENT function lets you assign a priority levels to each amplifi-er-input combination. This function lets you create a

Page 23

© 1996 Bogen Communications, Inc.50 Spring St., Ramsey, NJ 07446All rights are reserved. No part of thisdocument may be photocopied, repro-duced, or

Page 24 - User Operation

Programming5. Select a level and press ENT to save the selection (PROG LED willblink when selection has been entered).Important: You must press ENT af

Page 25

ProgrammingMic Set UpThis function lets you set the Microphone features: • Precedence Activation: N.O. = Normally Open - requires short between preced

Page 26

Programming4. The display shows A ALC ON indi-cating that MIC A ALC status isON.5. Press the NEXT or BACK but-tons to select ON or OFF. 6. Press ENT t

Page 27 - Programming

ProgrammingPresetsThis feature lets the installer adjust the power-up volume, bass and treble ofeach amp/channel-input combination. It also sets the

Page 28

ProgrammingNote: Press and hold arrow buttons to effect rapid changes involume. Quick presses of the buttons will effect single-stepchanges in volume

Page 29

ProgrammingVolume LimitThis function sets the maximum volume level that a user can select for anamp/channel-input combination.Warning: The Volume Lim

Page 30

Programming6. Once you have set the desired limit for an input, press ENT. ThePROG light will blink to indicate that data was stored.7. Select another

Page 31

ProgrammingInhibitThis function lets the installer inhibit the user’s ability to change the presetvolume and tone settings for a particular amplifier

Page 32

ProgrammingAux MuteThe Aux Mute allows paging over music. This function sets the volumelevel of each AUX input when a page is made. Upon completion

Page 33

ProgrammingAmplifier Link (PM-3180 Only)This function disconnects the power amplifier input from the preamp pro-cessing circuit and permits the additi

Page 34

Models PM-3000 & PM-3180User’s GuideOwner’s InformationModel NumberSerial Number_________________________Date of Purchase______________________Pla

Page 35

ProgrammingPasswordThis function lets the installer change the program mode password. 1. Enter programming mode and press the NEXT or BACK buttons un

Page 36

ProgrammingLabelsThis function lets you modify the names displayed for the current inputsource during user operation. For example, you can change the

Page 37

ProgrammingFactory DefaultsThis function lets you quickly erase all current configuration programmingand return the amplifier to its out-of-box config

Page 38

Testing & TroubleshootingTestingAssignmentTest: Remove all audio sources from Aux inputs. Connect an active audiosource to the lowest priority in

Page 39

Testing & TroubleshootingVol LimitTest: Manually select an Aux or Mic input. Press and hold the right arrowbutton until the display stops increme

Page 40

Testing & TroubleshootingMic never active• Check that the type of precedence setting is correct for the application(See page 26).• If mic is a con

Page 41

Getting HelpBogen has support available in case you have a problem with yourProMatrix. In order to make the most effective use of this service, pleas

Page 42

SpecificationsPM-3180Power Output:Amp 1: 100 wrmsAmp 2: 60 wrmsAmp 3: 20 wrmsOutput Taps:8-ohms, 25V and 70V transformer-coupled (balanced or unbal

Page 43 - Testing & Troubleshooting

SpecificationsPM-3000Outputs: 0dBV balanced outputs via screw terminal strips (all channels)0dBV unbalanced outputs via RCA jacks (all channels)Maximu

Page 44

50 Spring Street • Ramsey, NJ 07446www.bogen.com

Page 45

ContentsUnpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Packing List . . . . . . . . . . . . . . . . . . . . .

Page 46 - Getting Help

1UnpackingPacking ListThe ProMatrix carton contains the following components:1 - ProMatrix unit1 - Removable Control Panel*1 - Wireless Infrared Remot

Page 47 - Specifications

IntroductionDescriptionThe ProMatrix products are designed for sound reinforcement/distribution inmulti-room applications. The PM-3180 consists of thr

Page 48

IntroductionFeaturesThe ProMatrix units have the following features:• 2 Lo-Z balanced Mic inputs (Mic A is female XLR, Mic B is screw termi-nals). Mi

Page 49

Quick StartThis Quick Start section is intended to assist you in getting the ProMatrixunit up and running quickly so that you can become familiar with